Subject: | |
From: | |
Date: | Mon, 17 Feb 97 16:48:22 EST |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
I've heard that the general rule limiting blind vias is a 1:1 aspect
ratio. You are at it with the 16 mil holes & 16 mil depth. It seems
like you are doing the right things (i.e. vibration, etc.) so I'm not
sure what else to suggest.
MB
_____________________________ Reply Separator _________________________________
Subject: Blind vias & fine lines
Author: [log in to unmask] at SMTPLINK-HADCO
Date: 2/12/97 10:07 PM
Techneters,
Can anyone help? I am having two problem areas:
1) Blind via holes 16 mil diameter 16 mil deep contacting with 4
inner layers. I cannot always plate copper into all holes. If I do copper
plate them I cannot tin plate all the holes. I have vibrators on the
cathode movement frame and a giant to clout the fight bars with a 2 pound
hammer. Is there anything else I can do?!?
2) Circuits with 2 mil track and gaps. The finish required is
electroless nickel/immersion gold. How can this be done without causing
the tracks to short with nickel spikes?
Thanks in advance,
Roger Hammond
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To subscribe/unsubscribe send a message <to: [log in to unmask]> *
* with <subject: subscribe/unsubscribe> and no text in the body. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|