Charles Barker
02/14/97 03:09 PM
We are investigating switching from RMA and SA based fluxes to WS fluxes.
We notice much higher and inconsistent Ohmegameter readings with the WS
fluxes. Is there a better means of measuring Ionic contaminants when using
WS flux? What are others using to check how "clean" a WS processed assembly
is after wash?
Thanks in advance.