Subject: | |
From: | |
Date: | 08 Feb 97 23:05:50 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
int [log in to unmask]
To: INTERNET--MSBG
FROM: "Ravishankar VR"<W0292%YMS@msbg>
Hello everybody:
Here are some inputs regarding Assembly ESD from our Company's Production
Manager. Hope it is of use.
With Regards,
RAVISHANKAR VR --- Senior Development Engineer, GPDC,
Wipro GE Medical Systems Ltd, Bangalore, INDIA - 560 067
TEL:+91-80-845 2923/25 FAX:+91-80-845 2924 DIALCOM:7401-280 (GE only)
*** Forwarding note from W0444 --YMS 02/05/97 21:44 ***
To: W0292 --YMS
*** Reply to note of 02/05/97 12:51
From: Sripathy
Ravi can U pass on this info reg static charges in the shopfloor due to
Chairs and operators. I had tried out a different scheme to overcome such
problems which might possibly work!
* Use chairs only with cushions covered 100 percent cooton fabric covering.
* Avoid plastic/foam for places like the armrest. Use wood.
* Persons/Operators wear an antistatic apron.
* Persons active in the area also wear cotton socks only.or work bare foot
or use shoe bands for grounding.
* Use flaps for the seat and backrest of the chair made out of antistatic
fabric.(stitching to b done using cotton thread only).Take care not to use
Velcro pullouts for the flaps ! Use metallic buttons.
I hope some of these would answer the questions.
Sripathy
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *