Subject: | |
From: | es500yap@pts7 ( YAP CHOW LAN) |
Date: | Wed, 8 Jan 1997 16:00:07 +0800 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Hi,
Recently we encountered some assembled PCB returned from the field where
humidity is high and temp is low. Some vias and pads were found to be corroded
with copper chloride after SEM analysis and when corrosion production were
removed from the board, the affected part of the vias was degraded. This has
greatly affected the performance of the circuit.
The fabrication house claimed that they are not liable as there was not chloride
chemical used in their processes.
Does anyone has any insights to share? Could the assembly process contribute to
this corrosion?
Thanks in advance for any information shared.
stella yap
***************************************************************************