Hi TechNet -
I can't provide any info on how much resistance change occurs as
copper oxide grows but the question concerning the use of tin as a
contact surface is pretty straight forward. Tin oxide is not very
coherent - that is it doesn't bind tightly to the metallic surface it
grows from. Nickel oxide is an example of a coherent oxide. Most folks
using tin contacts follow two rules: a) they use high insertion forces
so that they make good contact with the tin and/or solder surface
under the oxide; b) they minimize the number of insertions that need
to be made - i.e. one or two at the most. There have been a number of
documented cases were tin oxide "spalls" off a contact surface leading
to fretting corrosion and/or wear problems. The old IPC spec
IPC-GH-850 "Handbook of Interconnection Contact Finishes" is a good
(but dated) reference to read. Good luck.
Dave Hillman
Rockwell Collins
[log in to unmask]
______________________________ Reply Separator _________________________________
Subject: RE: DES/FAB:switchpad contacts
Author: [log in to unmask] at ccmgw1
Date: 1/27/97 11:41 AM
Bill Parlin wrote:
Hello Technetters,
I am writing as a fabricator, but my question is about design...more
specifically, the functionality of keypad contacts.
In jobs we produce, the "contact coating" of the circuit geometry is usually
specified as carbon ink or electrolytic gold where the elastomeric button
makes contact. However, there is a new job in the design stage right now
that
utilizes a stainless steel pill/button to make contact, and (for various
reasons) I was wondering why bare copper would not work. The field
environment
is "indoor" but there is expected to be high temperture and humidity swings,
and the contact resistance must remain very, very low I am told (less than
what is achievable with a carbon coating), and remain so "forever".
I know solderability degrades as the copper surface ages and oxidizes, but
does it also become less conductive? Is there any other reason bare copper
should not be considered for this application?
Thanks in advance for your help.
Bill Parlin
I received a similar question from our design department:
Jan -
Right now I am working on a current profiler that's battery powered. One
side of the battery stacks will go against a PWB contact. I thought this
contact had to be gold to make it reliable, but my supervisor thinks it can
be a
typical solder coating or tin plating. Any thoughts? Do any of our
TECH-NET
downloads help with this question?
thanks
Sark
Thanks in advance for any inputs to these questions.
Jan Satterfield
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|