If you're not careful you'll have a lot in common with Hawk Chen.

I've tested various pre-clean processes prior to soldermask (LPI and dry
film)
over the years including:

	microetch with persulfate
	microetch with peroxide/sulfuric
	microetch with peroxymonosulfates
	'scotch brite' type scrub
	'brushlon' type scrub
	'scotch brite' type scrub followed by microetch
	microetch followed by Entec CU-56

None compares with pumice scrub for adhesion.

***************************************************************************