Dave

It sound like there just isn't enough free resin to fill the .025" 
cavities.  Thats laminating 18 oz copper!  I would not expect 6 pieces 
of prepreg to fill 18 oz copper.

If the volume of AVAILABLE resin was calculated and compared to the 
volume of the cavities which are trying to be filled, I predict that the 
cavities would have the greater volume.

Other factors, how much AVAILABLE resin gets squeezed out the edges, 
converting it to UNAVAILABLE resin?  AND  How far does the resin have to 
travel to fill the .025" cavities, does it have enough time to travel 
that far, ie the time between melting and curing?

I used to have a "rule of thumb" on the number of prepreg sheets needed 
to fill different copper thicknesses, but left it in a past life.  
Perhaps, others have developed similar layup aids?

George Franck
Raytheon E-Systems
Falls Church Va
These are the opinions the author, and do not reflect on Raytheon 
E-Systems, which is a pretty good place to work.



On Jan 23,  3:53pm, David Bergman wrote:
> Subject: FAB:
> 
> We received this via fax at the IPC office and are forwarding to 
technet 
> for comment.  Can anyone help?
> 
> Regards
> Dave Bergman, IPC
> 
> Statement of Process Problem
> 
> We are fabricating a 10 layer multilayer PWB with a 0.025" thick solid 
copper 
> heatsink (12" x 18") in its center, with 5 layers on each side.  This 
PWB has 
> been previously fabricated using a conventional multilayer layup 
methodology 
> with all layers assembled and then laminated in one package.  We 
experienced a
> low yield rate.  It was attributed to shorts caused by bubbles that 
formed 
> within the drilled holes of the heatsink.
> 
> We are currently experimenting with changing the production process to 
> laminate the PWB in two stages - first completely fill the holes in 
the 
> heatsink with prepreg, inspect and Second - layup the layers as usual. 
 The 
> heatsink undergoes pattern hole drilling, sanding and black oxide 
surface 
> preparation treatment.  The heatsink is assembled in the following 
package in 
> the Multilayer Lamination Room:  steel (12" x 18") lamination plate, 
aluminum
> sheet, 1 sheet tedlar release, 1 sheet each of 1080 prepreg, 2 sheets 
each of
> 106 prepreg, heatsink, 2 sheets each of 106 prepreg, 1 sheet each of 
1080 
> prepreg, 1 sheet tedlar release, 1 aluminum sheet, steel lamination 
plate.  
> The package undergoes lamination in a sealed vacuum "turkey" bag 
attached to 
> a vacuum bag pulling 30" hg, in a Wabash single opening lamination 
press for 
> 30 minutes at 375 deg. F & 4500# total force.  Upon visual inspection, 
the 
> heatsink/pregreg package exhibited bubbles in every drilled hole.  It 
this the
> result of resin starvation in the holes? 
>  
> 
> 
************************************************************************
***
> * TechNet mail list is provided as a service by IPC using SmartList 
v3.05 *
> 
************************************************************************
***
> * To unsubscribe from this list at any time, send a message to:       
    *
> * [log in to unmask] with <subject: unsubscribe> and no text.    
    *
> 
************************************************************************
***
> * If you are having a problem with the IPC TechNet forum please 
contact   *
> * Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]  
    *
> 
************************************************************************
***
> 
> 
> 
>-- End of excerpt from David Bergman


***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************