To add an additional thought to this process, I have used a higher solder
alloy (90Sn/10Pb) in order for this solder joint not to become molten and
lift of the board. I have also used one second U/V cure adhesive to retain onto the board the thermocouple wire.
Good luck
Ed Wong
Wongtronics Lab. Inc.
[log in to unmask]
On Fri, 10 Jan 1997 14:17:42 -0500 (EST) Allen Hertz
<[log in to unmask]> writes:
>Bill has a great point! I would like to expand on it a bit........
>
>The optimal process utilizes material properties to calibrate the
>profiling
>system. If you use the solder alloy which you are reflowing to secure
>the T/C to
>a particular pad, there will be a flat spot (transition temperature)
>in your
>profile. Then secure the T/C down in another area with epoxy. Chip
>bonder works
>great. This may alter your actual temperature ever so slightly.
>
>PS - it did clear as well as confuse ISO auditors who could not
>understand
>properties of materials!
>
>Enjoy the tip,
>Allen
>
>_______________________________________________________________________________
>
>Subject: Re: ASSY: thermocouple adhesive
>
>From: [log in to unmask] at ftl03
>
>Date: 1/10/97 1:04 PM
>
>
>
>Why not use solder its better !
>
>Bob Willis
>Process Engineering Consultant
>Electronic Presentation Services
>2 Fourth Avenue, Chelmsford, Essex CM1 4HA. England.
>Tel: (44) 01245 351502
>Fax: (44) 01245 496123
>Home Page: http://ourworld.compuserve.com/homepages/Bwillis
>Email: [log in to unmask]
>
>
>***************************************************************************
>* TechNet mail list is provided as a service by IPC using SmartList
>v3.05 *
>***************************************************************************
>* To unsubscribe from this list at any time, send a message to:
> *
>* [log in to unmask] with <subject: unsubscribe> and no text.
> *
>***************************************************************************
>* If you are having a problem with the IPC TechNet forum please
>contact *
>* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]
> *
>***************************************************************************
>
>
>***************************************************************************
>* TechNet mail list is provided as a service by IPC using SmartList
>v3.05 *
>***************************************************************************
>* To unsubscribe from this list at any time, send a message to:
> *
>* [log in to unmask] with <subject: unsubscribe> and no text.
> *
>***************************************************************************
>* If you are having a problem with the IPC TechNet forum please
>contact *
>* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]
> *
>***************************************************************************
>
>
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|