SANJAY,
THERE ARE TWO JEDEC STANDARDS FOR QFP'S.
MS-022; MQFP WITH BODY THICKNESSESS 2.0MM AND GREATER; COPLANARITY IS
0.1MM.
MS-026; TQFP WITH 1.0 AND 1.4MM BODY THICKNESSES; COPLANARITY IS 0.1MM
FOR 0.65MM LEAD PICH AND >.. 0.08MM FOR 0.5MM LEAD PITCH AND <..
MAURY
______________________________ Reply Separator _________________________________
Subject: GEN: Lead Coplanarity Spec??
Author: [log in to unmask] at smtp
Date: 1/22/97 10:53 AM
Technetters:
I have a couple of questions and would appreciate
any input...
1. What is the JEDEC/IPC spec on lead coplanarity
for QFP's?
2. Can anyone recommend any tinning houses that would
tin surface mount packages for us? I know one such place
is Corfin, are there any other popular ones?
Thank you
________________________________________________
Sanjay Rajan RF Communications Division
Harris Corporation Product Design Engineering
1680 University Avenue Phone: (716) 242-3923
Rochester, NY 14610 Fax: (716) 242-3174
________________________________________________
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|