On Jan 22, 8:25am, Steve Collins wrote:
> Subject: Re: Trace Damage from Breakaway Holes
> Robert Cronin wrote:
[snip]
> > Bob Cronin
> > Eastman Kodak
>
> Bob, Just a suggestion for your production people would be to switch
> from actually breaking parts out of panel to using pnumatic shears to
> cut the board out. I have used this methode in a past life with a
great
> deal of success.
>
Bob, Steve
In a past life, the pnumatic ram would "pop" and jar the board at the
end of the cut, sometimes causing problems. Switching to a hydrolic ram
fixed that problem. Since the hydrolic oil is non compressable, we got
a very even, smooth cut.
George Franck
--
George Franck Jr
Raytheon E-Systems
Falls Church Va.
"The opinions expressed are those of the author, and are not necessarily those of the Raytheon Corporation."
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|