Define "quick".  The shortest quality control SIR test that I know of is an
unpublished 24 hour test used by AT&T.  It is essentially the Bellcore 35/90
test for 24 hours and no bias.  This spot test is used to monitor the
process.  Same Bellcore pass/fail requirements.  We have done some of AT&T's
overflow testing in the past and it seems to work well if you have an
established baseline.

Doug Pauls
CSL

***************************************************************************