                      RE>>ASSY: calculation of accelerated*        7/11/96

I've seen such proposed models for accelerated testing of boards with respect to Temperature, Humidity, and Voltage, and I don't believe them.  Here's why:

1) There are many different potential mechanisms with this combined environment.  An acceleration factor should be specific to a *single* mechanism.  

2) Mechanisms which are dependent upon the amount of water that you have on a surface (such as corrosion) are strongly dependent upon RH, but it is not a linear function.  You may have less than a monolayer of water for low RH's, but above some critical RH (dependent upon contaminant type, location, quantity, and substrate factors), you'll get significantly more water.  The experimentally-determined curves that I've seen published years ago suggest a near linear relationship until you get to the critical RH and an exponential relationship above.  

3) Corrosion mechanisms are dependent upon voltage, but the relationship is *extremely* tough to quantify.  You can't say, for instance, that corrosion rate for 10V will be twice (or any multiple) that of 5V.  In some cases, corrosion rates with higher voltages will be *less* than for lower voltages, because of various passivation layers which form.  

I believe in Arrhenius-based relationships for many mechanisms, mainly those which are thermally-driven.  Because of this, it is tempting to try to do the same to come up with some kind of acceleration factors for both voltage and humidity.  Personally, I don't believe that it can be done, but I feel that there might be a way by trying to duplicate the perceived worst-case conditions.  

Just my $0.02,
Greg Bartlett
Mercury Computer Systems
Chelmsford, MA
[log in to unmask] 

--------------------------------------
Date: 7/11/96 10:42 AM
To: Greg Bartlett
From: [log in to unmask]
Nora, here are two proposed models that have been used to determine the
accelerated life of a PCB under Temperature, Humidity and Voltage. In each
case no values for constantans are given since these are material and design
dependant.

 1)  MTTF = ax[1 + bx(L*n)/V]  x(RH*c) x exp (E/(RxT))

      by T.L. WElsher etal, International Reliability Physics, 1980 pp 39-43

 2)   MTTF = a x(RH*b) xexp (E/(RxT)) + dx(L*2)/V)

      by J.P. Mitchel etal, Proceedings Printed Circuit World Convention II,
1981, 
      pp 80-93

where MTTF = Mean Time To Failure
          a, b, n, c,  d are all constants to be determined experimentally
for a given product, L conductor spacing, V applied DC voltage, RH relative
Humidity, R is gas constant and T absolute temperature, E is activation
energy.

Pratap Singh
RAMP Labs
(512) 255-6820

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to:           *
* [log in to unmask] with <subject: unsubscribe> and no text.        *
***************************************************************************


------------------ RFC822 Header Follows ------------------
Received: by mailgate.mc.com with SMTP;11 Jul 1996 10:40:37 -0400
Received: from firewall.mc.com (firewall [192.148.197.15]) by jericho (8.6.11/8.6.11) with SMTP id KAA04939 for <[log in to unmask]>; Thu, 11 Jul 1996 10:40:33 -0400
Received: by firewall.mc.com id AA19897
  (5.65c/IDA-1.4.4 for <[log in to unmask]>); Thu, 11 Jul 1996 10:40:32 -0400
Received: from ipc.org(168.113.24.64) by firewall via smap (V1.3)
	id sma019892; Thu Jul 11 10:40:15 1996
Received: from ipc.org by simon.ipc.org via SMTP (940816.SGI.8.6.9/940406.SGI)
	 id JAA08123; Thu, 11 Jul 1996 09:23:56 -0700
Resent-Date: Thu, 11 Jul 1996 09:23:56 -0700
Received: by ipc.org (Smail3.1.28.1 #2)
	id m0ueMYY-0000TIC; Thu, 11 Jul 96 09:17 CDT
Resent-Sender: [log in to unmask]
Old-Return-Path: <[log in to unmask]>
From: [log in to unmask]
Date: Thu, 11 Jul 1996 10:24:36 -0400
Message-Id: <[log in to unmask]>
To: [log in to unmask]
Subject: Re: ASSY: calculation of accelerated aging factor
Resent-Message-Id: <"Bk35b1.0.Fi8.rpGvn"@ipc>
Resent-From: [log in to unmask]
X-Mailing-List: <[log in to unmask]> archive/latest/5093
X-Loop: [log in to unmask]
Precedence: list
Resent-Sender: [log in to unmask]



***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to:           *
* [log in to unmask] with <subject: unsubscribe> and no text.        *
***************************************************************************



ATOM RSS1 RSS2