I would be more concerned about the potential damage that the additional
reflow process step has done to the integrity of the board rather than it's
age. I would suggest, as a minimum, microsectioning of some of the via holes
and assessing the bond integrity (ie no evidence of delamination or
disbonding), PTH copper plating integrity (no evidence of copper cracks or
interplane separation) and  overall solderability of the via holes (no
non-wetting conditions). Perhaps your supplier or an external laboratory
could perform the assessment. Just out of curiousity, why were the boards
re-reflowed in the first place???

Dave Rooke
Circo Craft - Pointe Claire

---------- reply separator --------------
>We stuff and solder (both wave and hand) small runs of PCBs (primarily PTH
>components. Our boare board requirements include individual packaging and
>boards no older than 6 months. A supplier recently shipped us boards that
>were re-reflowed 9 months after their original fabrication. Is this
>acceptable within A-610 for hi-rel commercial applications?  Thanks.
>
>Tom Moore
>Electro Plasma 
>Tom Moore
>
>***************************************************************************
>* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
>***************************************************************************
>* To unsubscribe from this list at any time, send a message to:           *
>* [log in to unmask] with <subject: unsubscribe> and no text.        *
>***************************************************************************
>
>
>

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to:           *
* [log in to unmask] with <subject: unsubscribe> and no text.        *
***************************************************************************



ATOM RSS1 RSS2