You need to specify what holes to be plugged so they do not plug your
holes that you used for electrical test. You can do this by a hole
size or a via pad size.
______________________________ Reply Separator _________________________________
Subject: PLUGGED VIAS
Author: [log in to unmask] at corp
Date: 10/14/96 10:24 AM
I have run into a problem with a board that has vias in smt pads. We
need all of the vias plugged, and I am told that solder mask is the best
way to do that. This is to ensure that a good vacuum is maintained for
our ATE equipment. That is the problem. I can not have a via covered
with solder mask on top of an smt pad. The board house I am using says
this is difficult for them because they have to determine which vias are
plugged and which are not. Anyone out there with any suggestions?
Thanks,
Barry Darnell
(864)627-8800 Ext. 231
[log in to unmask]
CD Electronics, Inc.
Printed Circuit Board Designer
***************************************************************************