Subject: | |
From: | |
Date: | Wed, 18 Sep 1996 22:04:34 -0400 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Dennis
The statement about "Hole wall dielectric/plated hole separation" is a direct
carry over from IPC-RB-276 Table 10 which as been in existence since 1992. It
is the intent to allow hole-hole-wall-pullaway to any extent as long as the
hole is not collapsed and the function is not degraded. This was a change
from IPC-ML-950 which only allowed 40% hole-wall-pullaway. This is the first
time any question has come up since RB-276 was issued and the suppliers and
users seem satisfied.
Phil Hinton
[log in to unmask]
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
|
|
|