It is possible to change you resin desmear process (e.g. permanganate) to
"roughen" the filled resin surface before the electroless plating. Several
photoimageable dielectric processes (e.g. IBM SLC) uses this technique to
achieve improved copper peel strength.
Mason Hu
Zycon Corporation
______________________________ Reply Separator _________________________________
Subject: GEN: Blind via Fill
Author: [log in to unmask] at corp
Date: 12/2/96 9:38 AM
Hello all,
I have a question on blind via which fill / partially fill with prepreg
resin during lamination. Assume an 8 layer board, blind via 1-6, SMOBC,
.062", standard in other ways....
ASCII Graphic
_______ _______ Copper Layer 1
xxxxxx|___A___|xxxxxx A = Copper Layer 1 in partially filled via hole
xxxxxx|xxxxxxx|xxxxxx
FR-4 | resin |FR-4 FR-4 "x" and plated via hole wall "|"
xxxxxx| blind |xxxxxx
-------x via x------- Copper layer 6
xxxxxxxxxxxxxxxxxxxxx
---------------------- Copper layer 8
In area "A", above, the resin fill does not go the the surface of the
board. This is a partially filled blind via, and is an acceptable
condition. However.... The surface of "A" is plated with electroless
and pattern plated. The electroless/plated copper has very poor
adhesion on the resin in the hole, and peels off in various subsuquent
processes, especially solder coat. I understand that the "fill" resin
surface is very smooth which causes the adhesion failure.
It is my assumption that this is a typical condition for "unfilled"
vias. Is this a vaild assumption?
Are there any situations when this condition poses is a problem?
Do others allow partially filled vias? IPC-RB-276 accepts a 60% fill
for buried vias, but silent on blind vias.
I know that others are trying to use this filled via construction as a
surface mount pad (God help you), what experiences do you have with
partially filled vias?
Thanks for the responces.
--
George Franck Jr
Raytheon E-Systems
Product Assurance Engineer
Falls Church Va
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|