Hi Dave: We are installing SMD's on an FR-4 palletized scored array.
It is 6-up, each 1.0" wide by 11.5" in length. Material Thickness is
.042" and I specified scoring depth to leave .015" material. Have been
doing approx. 500 assemblies every 7 weeks for approx. 2.5 years. Found
the trick to scoring is depth and parallelism of top and bottom V-cuts.
Hope this helps!
Bill Black
Medco
***************************************************************************