Take a look at:
"IPC-GH-850: Handbook of Interconnection Contact Finishes"
"Connector Reliability i The Military Environment", Stuart Koford,
Connection Technology, May 1989, pp. 19-22".
Both references have some good information on gold-copper
interactions. Also keep in mind that there is a difference between a
gold - copper galvanic reaction and a gold - copper diffusion
reaction.
Dave Hillman
Rockwell Collins
[log in to unmask]
______________________________ Reply Separator _________________________________
Subject: copper gold galvanic during OSP application
Author: [log in to unmask] at ccmgw1
Date: 9/18/96 6:44 PM
Does anybody have any information or experience with the above issue?
***************************************************************************