We have done multiple DSC runs on off the shelf FR4 laminate which clearly
show that postcuring occurs. Not done it on multilayer samples (yet).

David Whalley
Loughborough University

>(1)  Is inner layer core material completely cured when it comes from the 
>supplier?  One of our guys suggested Polyclad told him that it was not - 
>that was a surprise to us, if true.

***************************************************************************