TECHNET Archives

1996

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Received:
by ipc.org (Smail3.1.28.1 #2) id m0tuKSw-00005xC; Wed, 6 Mar 96 08:45 CST
Encoding:
16 TEXT
Old-Return-Path:
Date:
Wed, 06 Mar 96 07:47:00 MST
Precedence:
list
Resent-From:
Resent-Sender:
X-Status:
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/2992
TO:
From [log in to unmask] Mon Mar 11 17:
26:25 1996
Resent-Message-ID:
<"CFmB52.0.8n9.0KQFn"@ipc>
Subject:
From:
"Edwards, Ted A (AZ75)" <[log in to unmask]>
Return-Path:
X-Loop:
X-Mailer:
Microsoft Mail V3.0
Message-Id:
Parts/Attachments:
text/plain (19 lines)

     The recent TechNet message on the effect of nickel on high frequency 
transmission lines was of interest and we are seeking information on the 
following:
     We have several fabricators suggesting we replace hot air leveling with 
and alternative such as electroless nickel-immersion gold, electroless 
palladium, or just leave the surface bare with an organic surface protector. 
 The boards are Teflon based and dielectric constant can be as high as 10.8. 
 Sounds like nickel is not such a great idea, does anybody have experience 
or data on palladium or just leaving the surface bare on microwave boards? 
 What is the effect of Palladium?  Does the naturally occurring copper oxide 
on the bare board affect performance?

Ted Edwards
602-436-3027
[log in to unmask]