Boy,
your customer sure does not what he is doing. Performing tests at 70C/95%RH
almost guarantees condensed water on your test boards-- white stains is what
is left after the water dries off.
Even the Bellcore requirements are a problem and were created by some hand
waving arguments--they come from some old Bell Labs experiments, where the
test data never could be quantitatively correlated with actual product
behavior and let to the hypothesis of a threshold condition for CAF. That
goes even more for your test conditions which are sure to create extraneous
mechanisms, not just liquid water on your boards.----But I guess the customer
is always right.
Werner Engelmaier
Engelmaier Associates, Inc.
Electronic Packaging, Interconnection and Reliability Consulting
23 Gunther Street
Mendham, NJ 07945 USA
Phone & Fax: 201-543-2747
E-mail: [log in to unmask]
***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text. *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|