TECHNET Archives

1996

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Mime-Version:
1.0
Content-Type:
text/plain; charset=us-ascii
Old-Return-Path:
Date:
Wed, 11 Dec 1996 17:30:12 -0500
From [log in to unmask] Thu Dec 12 15:
55:00 1996
Precedence:
list
Resent-From:
Resent-Sender:
TechNet-request [log in to unmask]
Content-Transfer-Encoding:
7bit
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/8463
TO:
Return-Path:
<TechNet-request>
X-Status:
X-Loop:
Resent-Message-ID:
<"SOoQc3.0.2PL.IGqho"@ipc>
Subject:
From:
Bill Sturner x2855 <[log in to unmask]>
Received:
by ipc.org (Smail3.1.28.1 #2) id m0vXy6e-0000UGC; Wed, 11 Dec 96 17:30 CST
Sender:
X-Mailer:
Mozilla 2.01 (X11; I; HP-UX A.09.05 9000/735)
Message-Id:
Parts/Attachments:
text/plain (29 lines)
Does anyone have CTE, thermal conductivity, and strength data for
72Ag/28Cu brazing alloy?  I'm performing a thermal/stress analysis of a
system that is cooling from solidification of the brazing alloy (800C)
to room temp. and is then modified and cooled to -55C.  I'm sure the
properties are temperature dependent, but room temperature data would
get me in the ballpark.  Any help would be appreciated.

______________________________________________________________________________
Bill Sturner - Structural/Thermal Analysis   Voice: 609-338-2855
Lockheed Martin                            MARCALL:   8-794-2855
Government Communications Systems              FAX: 609-338-2555,4628
1 Federal Street                             Email:
[log in to unmask]
MS: OPS-2-A1
Camden, New Jersey 08102
______________________________________________________________________________

***************************************************************************
* TechNet mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to:           *
* [log in to unmask] with <subject: unsubscribe> and no text.        *
***************************************************************************
* If you are having a problem with the IPC TechNet forum please contact   *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask]      *
***************************************************************************



ATOM RSS1 RSS2