TECHNET Archives

1996

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Mime-Version:
1.0
Content-Type:
text/plain; charset=us-ascii
References:
Date:
Sun, 17 Nov 1996 14:17:33 -0500
Precedence:
list
Resent-From:
Resent-Sender:
TechNet-request [log in to unmask]
X-Status:
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/7788
TO:
Return-Path:
<TechNet-request>
X-Loop:
Received:
by ipc.org (Smail3.1.28.1 #2) id m0vPZ0s-0000UlC; Mon, 18 Nov 96 13:05 CST
Old-Return-Path:
Resent-Message-ID:
<"GIGMO3.0.QjD.9EBao"@ipc>
From [log in to unmask] Tue Nov 19 09:
14:41 1996
From:
"George Franck Jr" <[log in to unmask]>
Subject:
In-Reply-To:
[log in to unmask] "Re: Fatigue resistant high temp solder" (Nov 18, 12:52pm)
X-Mailer:
Z-Mail 4.0.1 (4.0.1 Apr 9 1996)
Message-Id:
<961117141735.ZM4263@ucpc206>
Parts/Attachments:
text/plain (30 lines)
On Nov 18, 12:52pm, [log in to unmask] wrote:
> Subject: Re: Fatigue resistant high temp solder
{clip)

>However, I am puzzled by to -55oC; I cannot imagine an actual 
>application down to -55oC--even the USAF no longer talks about -55oC  
>since no electronics actually experiences this temperature. 


You are right, our most recent USAF contract states -50oC operation, but 
still has a -55oC storage requirement.


-- 


George Franck Jr
Raytheon E-Systems
Product Assurance Engineer
Falls Church Va

***************************************************************************