We are currently performing HAST testing as per JEDEC std mentioned. We are
also using an Express Test 6000X system. Hast has a typical acceleration
factor of 20 to 1 so 1000 Hrs of 85C/85%RH can be done in 50 Hrs. The idea
is to use pressure to accelerate the failures.
Please call me or e-mail me for more information
Dario Sanchez
Engineering Manager
Mission Peak Services
510-498-1185
[log in to unmask]
***************************************************************************