TECHNET Archives

1996

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Received:
by ipc.org (Smail3.1.28.1 #2) id m0uGoqo-0000CPC; Tue, 7 May 96 10:38 CDT
Content-Type:
text/plain; charset=US-ASCII
Old-Return-Path:
Date:
Tue, 7 May 1996 11:44:59 -0400
Precedence:
list
Resent-From:
Message-ID:
Content-Transfer-Encoding:
7bit
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/3883
From [log in to unmask] Wed May 15 16:
45:15 1996
TO:
Return-Path:
<TechNet-request>
X-Status:
Content-Description:
cc:Mail note part
Subject:
From:
[log in to unmask] (mrosenfi)
X-Loop:
Mime-Version:
1.0
Resent-Message-ID:
<"_yLOc2.0.kYB.HwsZn"@ipc>
Resent-Sender:
TechNet-request [log in to unmask]
Parts/Attachments:
text/plain (36 lines)
     DON'T KNOW IF THIS WILL HELP.
     
     BUT, MANY YEARS AGO WHITE RESIDUE WAS OBSERVED ON COMPONENTS THAT HAD 
     BEEN FLUXED WITH A HIGHLY CHLORINATED FLUX..   IT WAS DETERMINED TO BE 
     SOLUBLE "ONLY" IN A DILUTED SOLUTION OF THE ORIGINAL FLUX..
     SORRY, THAT'S ALL I CAN OFFER.


______________________________ Reply Separator _________________________________
Subject: White residue/lead oxide
Author:  [log in to unmask] at smtp
Date:    5/7/96 10:16 AM


We have a white residue problem at another division that has been analyzed 
using FTIR and SEM EDAX that has shown it to be lead oxide.  The white residue 
is located on pads/solder fillets.  The following process is used:
     
a.  Yokota flow solder (preheat 220F topside, 495F solder pot (less than 3 
seconds), conveyor speed 3.5 ft/min) 
b.  Kester 197 foam fluxer (rma)
c.  Cleaner is Bioact EC7R in a Ney spray under immersion or ECD batch 
diswasher.  Temperature of EC7R 90-95F, Rinse waters 130F.
     
The white residue is observed after cleaning and is insoluble in alcohol 
water/EC7R.
     
Any input on things to look for would be greatly appreciated.  We are running 
tests at other divisions with different flux chemistries/board design/process 
parameters.
     
[log in to unmask]
     