Mime-Version: |
1.0 |
Content-Type: |
text/plain; charset="us-ascii" |
Old-Return-Path: |
|
Date: |
Thu, 6 Mar 1997 06:16:45 -0500 (EST) |
Precedence: |
list |
Resent-From: |
|
Resent-Sender: |
|
X-Status: |
|
Status: |
O |
X-Mailing-List: |
|
X-Sender: |
|
TO: |
|
Return-Path: |
<DesignerCouncil-request> |
X-Loop: |
|
From [log in to unmask] Thu Mar 6 14: |
41:50 1997 |
Subject: |
|
From: |
|
Received: |
by ipc.org (Smail3.1.28.1 #2)
id m0w2b0x-0007zVC; Thu, 6 Mar 97 05:07 CST |
Resent-Message-ID: |
<"oXW2Y2.0.a1G.ULg7p"@ipc> |
X-Mailer: |
Windows Eudora Light Version 1.5.2 |
Message-Id: |
|
Parts/Attachments: |
|
|
>Date: Wed, 05 Mar 1997 09:02:11
>To: [log in to unmask] (Mike Modrzejewski)
>From: john balchunas <[log in to unmask]>
>Subject: Re: SMTTraces
>
>Hello Mike, I came across the following info in Surface Mount Design and
Land Pattern standard IPC-SM-782A section 3.6.2.2..."Wide conductors
connecting to a land area can act as a solder thief...Narrow the conductor
as it enters the land area. Maximum conductor width should be .025
mm....The minimum conductor length should be .025 mm." Hope this helps! John
>
>
>At 06:54 AM 3/4/97 CST, you wrote:
>>
>>
>>Hi my name is Michael Modrzejewski
>>Iam looking for some information on trace width going into SMT pads.
>>Is there any problems with a .025 trace going into a 1206,0805 or 0603 pads ?
>>IS there a rule of thumb for this ?
>>
>>MOJO
>>
>>-------------------
>>Mike Modrzejewski
>>Teltrend, Inc.
>>St. Charles, Il
>>[log in to unmask]
>>-------------------
>>
>>***************************************************************************
>>* The mail list is provided as a service by IPC using SmartList v3.05 *
>>***************************************************************************
>>* To unsubscribe from this list at any time, send a message to: *
>>* [log in to unmask] with <subject: unsubscribe> and no text.*
>>***************************************************************************
>>* If you are having a problem with the DesignerCouncil, please contact *
>>* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
>>***************************************************************************
>>
>>
>
***************************************************************************
* The mail list is provided as a service by IPC using SmartList v3.05 *
***************************************************************************
* To unsubscribe from this list at any time, send a message to: *
* [log in to unmask] with <subject: unsubscribe> and no text.*
***************************************************************************
* If you are having a problem with the DesignerCouncil, please contact *
* Dmitriy Sklyar at 847-509-9700 ext. 311 or email at [log in to unmask] *
***************************************************************************
|
|
|