DESIGNERCOUNCIL Archives

1996

DesignerCouncil@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Received:
by ipc.org (Smail3.1.28.1 #2) id m0uvpTc-0000Q9C; Wed, 28 Aug 96 13:36 CDT
Content-Type:
text/plain; charset=us-ascii
CC:
References:
Date:
Wed, 28 Aug 1996 14:45:24 -0400
Precedence:
list
Resent-From:
Resent-Sender:
DesignerCouncil-request [log in to unmask]
MIME-Version:
1.0
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/1938
TO:
Doug Brooks <[log in to unmask]>
Return-Path:
<DesignerCouncil-request>
X-Status:
X-Loop:
Old-Return-Path:
Resent-Message-ID:
<"F6TaI1.0.ttJ.l699o"@ipc>
Subject:
From:
[log in to unmask] (Doug McKean)
Content-Transfer-Encoding:
7bit
From [log in to unmask] Thu Aug 29 11:
17:56 1996
X-Mailer:
Mozilla 2.0 (Win95; I)
Message-ID:
Parts/Attachments:
text/plain (54 lines)
Doug, 

> See Printed Circuit Design Magazine, August 96
> "The Effects of Vias on PCB Traces" where this
> effect was explicitly looked for and NOT found.
> In general, there is no practical difference in where
> you reference to, assuming reasonable ac filtering on
> the various power planes. This is especially true
> if your trace is between a power and a ground plane.
> But in the study referenced in the article, there
> were no ill effects even when a trace moved several
> layers and referenced to a completely different plane!
> 
> Nevertheless, it is good practice to try to keep the
> trace confined between a single pair of planes.
> 
> Doug Brooks

Oh boy, I knew this was going to be a can of worms! 

It is very specific case oriented especially as you noted 
with high frequency.  But, someone comes on the net and 
has a general problem, it's difficult to get a good handle 
on it to say blanketly yes or no. 

I would beg to differ with the article (believe me I'm not 
trying to start a fight).  Having a controlled impedence 
line from one reference plane drop vertically down several layers 
to another refernce plane for controlled impedence MAY be asking 
for trouble.  The impedence of the line vertically is uncontrolled 
thus causing an impedence "bump" with the trace. 

I don't disagree with what anyone has said.  Just fears of my own.

Doug

*******************************************************
Doug McKean
[log in to unmask]
-------------------------------------------------------
The comments and opinions stated herein are mine alone,
and do not reflect those of my employer.
-------------------------------------------------------
*******************************************************

****************************************************************************
* The mail list is provided as a service by IPC using SmartList v3.05      *
**************************************************************************** 
* To unsubscribe from this list at any time, send a message to:            *
* [log in to unmask] with <subject: unsubscribe> and no text. *
****************************************************************************



ATOM RSS1 RSS2