Dear members,
I am promoting mecseal finish for doubleside SMD jobs to our
customers.
One customer pointed out the following problem.
Two mounting holes(pth) is taped during wawesoldering and subsequently
brackets are fixed.He needs to ground the bracket and nut should make
electrical contact with land surrounding the fixingholes.Since the
fixing holes are covered with tape and subsequently tape is removed
meseal is not removed in that part.This will lead to no electrical
contact between the nut and the hole including land surrounding
Any suggestion to over come this problem please.May be some design
alternative to overcome this problem
Since OSP enteck etc. are in existence for quitesometime I think
someone might have this problem and overcome also.
Thanks in advance for any response
R.Srinivasan
Engineering mgr
Likom PCB SDN BHD
Malacca
Malaysia