TECHNET Archives

1995

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Condense Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Received:
by ipchq.com (Smail3.1.28.1 #2) id m0sgw5A-0000GnC; Fri, 11 Aug 95 10:33 CDT
Content-Type:
TEXT/PLAIN; charset=US-ASCII
Old-Return-Path:
<buetmi>
Date:
Fri, 11 Aug 1995 10:33:07 -0500 (CDT)
Precedence:
list
From [log in to unmask] Sat Apr 27 14:
31:31 1996
cc:
MIME-Version:
1.0
Status:
O
X-Mailing-List:
<[log in to unmask]> archive/latest/843
TO:
Return-Path:
X-Status:
Resent-Sender:
Resent-Message-ID:
<"GjeKB.0.OBI.tWtAm"@ipc>
Subject:
From:
Mike Buetow <[log in to unmask]>
X-Loop:
In-Reply-To:
<9508110735.AA16936@dazix>
Resent-From:
Message-ID:
<Pine.3.89.9508111008.A17035-0100000@ipc>
Parts/Attachments:
TEXT/PLAIN (37 lines)
Keith:

>   a) How can I find the latest additions and sizes to the RLP series.

The IPC Surface Mount Land Patterns Subcommittee is developing an 
amendment to IPC-SM-782A (August 1993). The amendment is currently under 
review by the committee chair. We have not set a publishing date.

>   b) Where can I obtain information and sizes of footprints that are
>      not yet coded as RLP numbers.

Land patterns for components developed following the release of 
IPC-SM-782A may be calculated using the forumulas found on pages 10-14 of 
IPC-SM-782A. These formulas take into account the width of the part (lead 
termination to lead termination), the minimum amount of lead length, the 
overall component length, the target heel fillet, and tolerances for 
fabrication and assembly equipment.

Section 3.3.3.4 describes how users can tailor the IPC RLP to their own 
libraries. In lieu of an updated standard, you might want to follow this 
method.

>   c) Is there a forum for this type of detailed design discussion.

For now, [log in to unmask] or [log in to unmask] may be used for 
design questions/discussion.