Thank you for the response Morgan, it helps greatly.
Best,
-Jeffrey
This message has been marked as Public on 6/15/2020 8:36 AM.
-----Original Message-----
From: TechNet <[log in to unmask]> On Behalf Of Morgan Viggers
Sent: Thursday, June 11, 2020 12:05 PM
To: [log in to unmask]
Subject: Re: [TN] IPC class 3A?
CAUTION: Email originated from outside of Cubic.
I can't speak for the J-std or A-610 specs, but the Class 3A requirements in the IPC-6012 spec did change with the release of the "Space Addendum".
IPC-6012C had a section for Class 3/A requirements - this was dropped in the 6012D release and those requirements now appear to be contained in 6012DS (Space addendum).
The "A" in Class 3/A most definitely does not refer to the A/B/C producibility levels outlined in the IPC-222x design series!
Morgan Viggers
Field Applications Engineer
ISU Petasys
503.675.3877
-----Original Message-----
From: Jenkins, Jeffrey (US) [mailto:[log in to unmask]]
Sent: Thursday, June 11, 2020 10:58 AM
To: [log in to unmask]
Subject: [TN] IPC class 3A?
Good Morning folks,
I have a question that was posed to me recently. I vaguely recall that there used to be a class 3A for aerospace, probably for the J-std-001 and perhaps IPC-A-610. After a bit of searching, I'm not finding anything on class 3A. So I'm wondering, has that been superseded by the Space Addendum?
I had one person indicate they believe the "A" stood for the Producibility level, but I hadn't hear that before and don't believe that there is a direct colleration. I hope I'm not mistaking.
Thank you for any assistance in clarification that you may be able to provide.
Best,
Jeffrey A. Jenkins, CID+
Principal Engineering Designer
Cubic Mission Systems