aha, notice this is TechNet not software hack forum. in those type
of forum it is routinely called each other "stupid
questions"... ;-). Hardware/software difference ....
jk
On Feb 27, 2020, at 4:40 PM, Stadem, Richard D wrote:
> You sure are welcome, Jeffrey.
> And never, ever, start off a posting on this forum again with an
> apology for asking a dumb question. There are no dumb questions,
> and even after 45 years in this business I (and all of us) are just
> as much of a "newbie" as you are! There is simply too much to learn.
>
> Odin
>
> -----Original Message-----
> From: TechNet <[log in to unmask]> On Behalf Of Jenkins, Jeffrey (US)
> Sent: Thursday, February 27, 2020 3:08 PM
> To: [log in to unmask]
> Subject: Re: [TN] [External] [TN] No-Clean (ROL0) question....
>
> Doug and Richard,
>
> Thank you both very much I do appreciate both of your assistance.
> Something in the back of my mind (probably from IPC Cleanliness
> conferences!) said it’s not the best thing to do. I also went and
> pulled the IPC-CH-65 Paul had mentioned prior and I look forward to
> reading it.
>
> Best,
>
> -Jeffrey
>
>
> From: Douglas Pauls <[log in to unmask]>
> Sent: Thursday, February 27, 2020 12:55 PM
> To: TechNet E-Mail Forum <[log in to unmask]>; Jenkins, Jeffrey (US)
> <[log in to unmask]>
> Subject: Re: [External] [TN] No-Clean (ROL0) question....
>
> CAUTION: Email originated from outside of Cubic.
>
> Jeffrey,
> I will send you a document that I drew up about 12 years ago,
> together with the late Dr. Bill Kenyon. It talks about no-clean
> fluxes and why someone would choose to clean a no-clean flux. You
> might find it of benefit.
>
> There are also a number of excellent papers by Dr. Mike Bixenman of
> Kyzen on the nature of fluxes under QFNs that more addresses what
> can happen if those low solids residues do not get to the proper
> temperature.
>
> Douglas Pauls | Principal Materials and Process Engr | Advanced
> Operations Engineering COLLINS AEROSPACE
> 400 Collins Road NE, MS 108-101, Cedar Rapids, IA 52498 USA
> Tel: +1 319 295 2109 | Mobile: +1 319 431 3773
> [log in to unmask]<https://urldefense.com/v3/__http:/
> collins.com__;!!Ooxr18I!SpjguiMwPUXmAyuL-
> TOQ6oNFndlaWAj2leYz1JtaVdafwZmwGo_HqZ-Xr1tX1Ea26VMJ$>
> [log in to unmask]<mailto:[log in to unmask]
> lins.com> for all Export Compliant Items
>
>
> On Thu, Feb 27, 2020 at 2:21 PM Jenkins, Jeffrey (US)
> <[log in to unmask]<mailto:[log in to unmask]>> wrote:
> Fellow TechNetters,
>
> I apologize if this may seem like a newbie question and if so I
> apologize.
> I've used OR fluxes and RO fluxes and have always had them removed
> by the cleaning process as most of the products that I work on have
> an expected life of 10+ years. We've typically validated the
> amount of WOA and Chlorides and set baselines for those.
>
> Someone posed me a question about cleaning no-cleans. Even though
> in a perfect world a no-clean flux should be 100% inactive after
> reflow, I'm betting that's never perfectly the case. So my view
> and response was that based on the life span and end use
> environment, my concern would be humidity/moisture mixing with the
> residual material and in the long term increasing the risk of
> dendritic growth and other things. Am I off the mark?
>
> Thanks,
>
> Jeffrey A. Jenkins, CID+
> Principal Engineering Designer
> Cubic Mission Solutions
>
> Note: This email and any attachments may contain confidential or
> proprietary information.
> If you are not the intended recipient, any use or distribution is
> prohibited; please notify the sender and delete from your system.
|