Priceless detail for me Robert.

Many thanks. 

Rich  Kraszewski 
Senior Staff Process Engineer
Phone: (920) 969-6075

* * * * * * * * CONFIDENTIALITY NOTICE * * * * * * * *

This e-mail and any attachments are confidential from Plexus Corp. and may contain information which is privileged, confidential, and/or protected by non-disclosure agreements.  They are intended solely for the use of the named addressee(s).  .  Any unauthorized use or disclosure may be unlawful.  If you are not a named addressee, you must not use, disclose, retain or reproduce all or any part of the information contained in this e-mail or any attachments If you have received this transmission in error, please destroy it and notify us immediately by return e-mail or by calling + 1 888 208 9005.




-----Original Message-----
From: Hill, Robert J [mailto:[log in to unmask]] 
Sent: Tuesday, October 30, 2018 12:24 PM
To: TechNet E-Mail Forum <[log in to unmask]>; Richard Kraszewski <[log in to unmask]>
Subject: RE: Requirements for Adhesive for Space Application

A list of material outgassing values can be located at:

https://ntrs.nasa.gov/search.jsp?R=19970027853

To meet NASA Outgassing requirements, TML must be less than 1% and the CVCM must be less than 0.1%. Both requirements must be met to be considered a NASA Low Outgassing material.

Robert
__________________________________________________
Lockheed Martin Space                         

-----Original Message-----
From: TechNet <[log in to unmask]> On Behalf Of Richard Kraszewski
Sent: Monday, October 29, 2018 1:36 PM
To: [log in to unmask]
Subject: EXTERNAL: Re: [TN] Requirements for Adhesive for Space Application

Thanks Ioan. 
 So is there an actual pass/fail criteria in ASTM E595?

Rich  Kraszewski 
Senior Staff Process Engineer
Phone: (920) 969-6075

* * * * * * * * CONFIDENTIALITY NOTICE * * * * * * * *

This e-mail and any attachments are confidential from Plexus Corp. and may contain information which is privileged, confidential, and/or protected by non-disclosure agreements.  They are intended solely for the use of the named addressee(s).  .  Any unauthorized use or disclosure may be unlawful.  If you are not a named addressee, you must not use, disclose, retain or reproduce all or any part of the information contained in this e-mail or any attachments If you have received this transmission in error, please destroy it and notify us immediately by return e-mail or by calling + 1 888 208 9005.




-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Tempea, Ioan
Sent: Monday, October 29, 2018 12:56 PM
To: [log in to unmask]
Subject: Re: [TN] Requirements for Adhesive for Space Application

Hi Rich,

You'll need to start with ASTM E595, outgassing. This will allow the adhesive into your usable chemicals database.

Then its program related, you'll thermally cycle, vibrate, shock, etc. (per program requirements) each substrate/component combination you need. Guidelines for each required test method are in MIL-883. I don't believe there is a more general way.

Cheers,

Ioan

-----Message d'origine-----
De : TechNet [mailto:[log in to unmask]] De la part de Richard Kraszewski Envoyé : October 29, 2018 12:01 PM À : [log in to unmask] Objet : [TN] Requirements for Adhesive for Space Application

Can anyone  tell me what defense industry standards are required to qualify an adhesive for space applications?
I seem to recall something may have of existed in Mil Std-883?

Rich  Kraszewski
Senior Staff Process Engineer
Phone: (920) 969-6075

* * * * * * * * CONFIDENTIALITY NOTICE * * * * * * * *

This e-mail and any attachments are confidential from Plexus Corp. and may contain information which is privileged, confidential, and/or protected by non-disclosure agreements.  They are intended solely for the use of the named addressee(s).  .  Any unauthorized use or disclosure may be unlawful.  If you are not a named addressee, you must not use, disclose, retain or reproduce all or any part of the information contained in this e-mail or any attachments If you have received this transmission in error, please destroy it and notify us immediately by return e-mail or by calling + 1 888 208 9005.