TECHNET Archives

September 2018

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Stadem, Richard D" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Stadem, Richard D
Date:
Thu, 20 Sep 2018 16:57:42 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (1 lines)
Yes, Wayne, those are all excellent design practices with pretty much any type of mechanical MEMs device!



-----Original Message-----

From: TechNet [mailto:[log in to unmask]] On Behalf Of Wayne Showers

Sent: Thursday, September 20, 2018 11:29 AM

To: [log in to unmask]

Subject: Re: [TN] 6-axis MEMS Gyroscope/Accelerometer assembly



It's not the fall that kills you, it's the sudden stop at end.



I liked Richard Stadem's Norway work.  I am limited to having built products to survive 15,500gs of acceleration and products to survive 500Hz of vibration, but not together.

As for delicacy, the problem is that the jerk force is often times a lot higher than we realize.  Mostly, when handling accelerometers, I recommended a dual foam protection system, a layer of rigid or semi-rigid foam with another layer of soft foam to reduce the jerk force.

Most applications recommend an adhesive perimeter bond to improve survivability.

Recommendation at least 1 inch of soft foam in both component and assembly packaging.


ATOM RSS1 RSS2