		If nodes are available on the surface you might be better off isolating the location using TDR.
Use a pulse generator with a rise time of 9pS if available use a flight time of 150 pS/ inch as a guide. Take the pulse transit time from injection point/ divide by 2 as the timing is here and back then divide the time in pS by 150 and that distance in inches can be worked out by reviewing the gerbers
		

		Sent from my iPad Pro
	





On Tue, Jun 5, 2018 at 8:44 AM -0700, <[log in to unmask]> wrote:










Hello Fellow TechNetters:

   I didn't get too many responses on my initial above inquiry.   Therefore, I will post once again.

Victor,

From: Hernandez, Victor G
Sent: Wednesday, May 16, 2018 1:24 PM
To: TechNet E-Mail Forum
Cc: Hernandez, Victor G
Subject: PCBA Short detection/isolation, Flir IR Thermacam SC2000, Thermal Imaging

Fellow TechNetters:

   Does anyone out there have experience that they can share on the above stated subject?    I can be contacted off line if so desired.

Victor,