Placing 0201s Ionizers in the covertape pull back and pick-up point is becoming a must...... several  P&P brand already provide tape feedrs with ionizer embedded in the front pick-up point of feeder itself. 
PCB (mainly it is like an insulator) could also be charged by electrostatic along the travel from screen printing to Reflow oven through conveyor belts and PCB remains charged ( Try by a field meter and you'll see) I've got experience of  > 1Kv/ inch (RH 35%) on top a PCB once out from screen printer along P&P and before oven....


-----Messaggio originale-----
Da: TechNet [mailto:[log in to unmask]] Per conto di Stadem, Richard D
Inviato: giovedì 10 maggio 2018 22:10
A: [log in to unmask]
Oggetto: Re: [TN] R: [TN] 0201 tombstoning

Yes, controlling static cling on the cover tape is essential for 0201s. If the overall humidity cannot be controlled, or if it affects paste printing rheology, it is sometimes a good idea to place an ionizer right over the pick/place feeders.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Jared Robertson
Sent: Thursday, May 10, 2018 2:54 PM
To: [log in to unmask]
Subject: Re: [TN] R: [TN] 0201 tombstoning

Here is what I got from the component manufacture  

We recommend that the customer check and control the environmental conditions during the pick and place process. Low humidity conditions can aggravate static electricity on the components and cause "jumping" from the carrier tape after removing the cover film. In particular, relative humidity is strictly maintained at 40-70%.


We are not meeting the humidity requirements

Jared 


---