TECHNET Archives

May 2018

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Robert Kondner <[log in to unmask]>
Reply To:
Date:
Thu, 24 May 2018 10:54:57 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (21 lines)
A change in characteristic impedance (crushing at a point) will have little
effect. Consider the wavelengths of the signal as compared to the length of
the crush. Anything under wave/20 is almost a don't care. You can look up
the effects of vias on log traces as a similar example.

Bob K.

-----Original Message-----
From: TechNet <[log in to unmask]> On Behalf Of [log in to unmask]
Sent: Thursday, May 24, 2018 10:28 AM
To: [log in to unmask]
Subject: [TN] Match Pair Wires with ground shield

Fellow TechNetters:

   Will the output signals integrity/impedance of match pair wires with
ground shield be effective by an external compression force of the
harness/bundle?

Victor,

ATOM RSS1 RSS2