Hi Guy & Doug,

I have Guy's photos posted, he has two charts, I combined them both into
one *.jpg image here:

http://stevezeva.homestead.com/X-ray_dosimeter_charts.jpg

Steve

On Fri, Apr 13, 2018 at 9:16 AM, Douglas Pauls <
[log in to unmask]> wrote:

> Guy, all graphics get stripped out.
>
>
> Doug Pauls
> Principal Materials and Process Engineer
> Rockwell Collins
>
> On Fri, Apr 13, 2018 at 10:09 AM, Guy Ramsey <[log in to unmask]> wrote:
>
> > We found the situation sufficiently frightening to prompt an evaluation
> of
> > our AXI machine. I promised to let the Technet know what we found. I am
> not
> > at liberty to share all the details of the test. But, if you use AXI
> > equipment and you are not concerned, you should be.
> >
> > These graphics shows where I placed the dosimeters on a transparent
> > carrier. Red is above 100 rad (si) yellow is between 10 and 100 rad.
> Green
> > is less than 10.
> >
>



-- 
Steve Gregory
Kimco Design and Manufacturing
Process Engineer
(208) 322-0500 Ext. -3133

-- 



This email and any attachments are only 
for use by the intended 
recipient(s) and may contain legally privileged,
 confidential, proprietary 
or otherwise private information. Any 
unauthorized use, reproduction, 
dissemination, distribution or other 
disclosure of the contents of this 
e-mail or its attachments is strictly
 prohibited. If you have received 
this email in error, please notify the
 sender immediately and delete the 