Hi Jared,

use Ionizer.....

There are few Pick and Place Brand that provide  Tape Feeders  already equipped by ionizer on the pick-up area just for small chips.

Gabriele

-----Messaggio originale-----
Da: TechNet [mailto:[log in to unmask]] Per conto di Jared Robertson
Inviato: martedì 24 aprile 2018 18:39
A: [log in to unmask]
Oggetto: [TN] 01005's placment problems

Hello, everyone 

We are trying to place 01005’s and are have troubles with the components (caps) jumping out of the tape. There is some kind of static charge causing the part to attract to the cover tape and stand up in the pocket. Has anyone seen this? Is there a way to eliminate the charge?  One thought is maybe our X-ray counter is placing the charge on the reel. Not sure yet.

Thanks 

Jared 


---