Hi Gil,
Do you cross sectioned a PCB in the same location before hand soldering?
Best Regards
Reuven
נשלח מה-iPhone של ראובן רוקח
ב-19 באפר׳ 2018, בשעה 15:37, Stadem, Richard D <[log in to unmask]> כתב/ה:
> Initially, this does NOT appear to be from Z-axis expansion, but rather resin recession. However, that could have been caused by overheating during soldering or rework also.
>
> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]] On Behalf Of Steve Gregory
> Sent: Thursday, April 19, 2018 8:32 AM
> To: [log in to unmask]
> Subject: Re: [TN] R: [TN] R: [TN] PCB failure
>
> Hi Gil,
>
> Just got into work and I have your image posted:
>
> http://stevezeva.homestead.com/SmartSelect_20180419-091742_Gaaiho_PDF.jpg
>
> Steve
>
>> On Thu, Apr 19, 2018 at 6:29 AM, Zilber Gil <[log in to unmask]> wrote:
>>
>> I sent it to Steve.
>> I am also attaching it to this mail, so you can look at it.
>> Thanks,
>> Gil
>>
>>
>>
>> נשלח מסמארטפון ה-Samsung Galaxy שלי.
>>
>>
>> -------- הודעה מקורית --------
>> מאת: [log in to unmask]
>> תאריך: 19.4.2018 14:24 (GMT+01:00)
>> אל: [log in to unmask]
>> נושא: Re: [TN] R: [TN] R: [TN] PCB failure
>>
>> Dell - Internal Use - Confidential
>>
>> Was the photo uploaded to Steve Geogory. I was not able to open the
>> drive google url link. Curious to the photo of IPsep.
>>
>> Victor,
>>
>> -----Original Message-----
>> From: TechNet [mailto:[log in to unmask]] On Behalf Of David Hillman
>> Sent: Thursday, April 19, 2018 6:57 AM
>> To: [log in to unmask]
>> Subject: Re: [TN] R: [TN] R: [TN] PCB failure
>>
>> Hi Gil - if you have the resources, you should put that cross section
>> in the SEM and look for possible resin smear on the inner layer/PTH interface.
>> Resin smear could cause the defect you are seeing.
>>
>> Dave Hillman
>> Rockwell Collins
>> [log in to unmask]
>>
>>
>>> On Thu, Apr 19, 2018 at 4:02 AM, Zilber Gil <[log in to unmask]> wrote:
>>>
>>> Thanks
>>> It is a leaded hand soldering of that device. I will check if the
>>> other failed location has hand soldering also. The material is a
>>> high tg material (Isola 370 HR).
>>> Regards,
>>> Gil
>>>
>>>
>>>
>>> נשלח מסמארטפון ה-Samsung Galaxy שלי.
>>>
>>>
>>> -------- הודעה מקורית --------
>>> מאת: SALA GABRIELE <[log in to unmask]>
>>> תאריך: 19.4.2018 10:46 (GMT+01:00)
>>> אל: 'TechNet E-Mail Forum' <[log in to unmask]>, Zilber Gil <
>>> [log in to unmask]>
>>> נושא: R: [TN] R: [TN] PCB failure
>>>
>>> Gil,
>>>
>>> you could show the picture to TNetters by mailing it to Steve
>>> Gregory [log in to unmask] whom very kindly support us when we need
>>> to attach picture (many thank Steve for you service) so all the
>>> TNetters will see the picture.
>>>
>>> I have seen your picture, yes it is a IPS (Inner Plane Separation)
>>> from PTH.
>>> It may be due to thermal stress in Z assy, but why ?
>>> You made baking to PCB so it should not be a matter of internal over
>>> pressure due to moisture blow-off.
>>>
>>> Or may be too low Tg of laminate or high CTE in Z assy ?
>>> Are you running Lead Free Reflow ?
>>>
>>> Etc...
>>> Gabriele
>>>
>>>
>>> -----Messaggio originale-----
>>> Da: TechNet [mailto:[log in to unmask]] Per conto di Zilber Gil
>>> Inviato: giovedì 19 aprile 2018 10:27
>>> A: [log in to unmask]
>>> Oggetto: Re: [TN] R: [TN] PCB failure
>>>
>>> Thanks Gariele,
>>> The PCB is new, and it was baked before assembly.
>>> Thanks,
>>> Gil
>>>
>>>
>>>
>>> נשלח מסמארטפון ה-Samsung Galaxy שלי.
>>>
>>>
>>> -------- הודעה מקורית --------
>>> מאת: SALA GABRIELE <[log in to unmask]>
>>> תאריך: 19.4.2018 10:07 (GMT+01:00)
>>> אל: [log in to unmask]
>>> נושא: [TN] R: [TN] PCB failure
>>>
>>> Hi Gil,
>>>
>>> did you handled correctly PCB against moisture absorption ? Like
>>> guide lines of IPC-1601A ?
>>> Shelf life of your PCB ?
>>> Any Baking before reflow?
>>>
>>> Gabriele
>>>
>>> PS: no picture is attached
>>>
>>> -----Messaggio originale-----
>>> Da: TechNet [mailto:[log in to unmask]] Per conto di Gil ZIlber
>>> Inviato: giovedì 19 aprile 2018 09:27
>>> A: [log in to unmask]
>>> Oggetto: [TN] PCB failure
>>>
>>> Hello Tech,
>>> We encounter a PCB discontinuing. Cross section shows conductor
>>> separation from TH.
>>> The PCB manufacturer claims it is due to overheating during assembly.
>>> To me, it looks like bad PCB manufacturing.
>>> Please look at the picture and give me your feedback.
>>> Thank you
>>>
>>>
>>> ---
>>> Questa e-mail è stata controllata per individuare virus con Avast
>>> antivirus.
>>> https://www.avast.com/antivirus
>>> The information contained in this communication is proprietary to
>>> Israel Aerospace Industries Ltd. and/or third parties, may contain
>>> confidential or privileged information, and is intended only for the
>>> use of the intended addressee thereof. If you are not the intended
>>> addressee, please be aware that any use, disclosure, distribution
>>> and/or copying of this communication is strictly prohibited. If you
>>> receive this communication in error, please notify the sender
>> immediately and delete it from your computer.
>>>
>>>
>>> The information contained in this communication is proprietary to
>>> Israel Aerospace Industries Ltd. and/or third parties, may contain
>>> confidential or privileged information, and is intended only for the
>>> use of the intended addressee thereof. If you are not the intended
>>> addressee, please be aware that any use, disclosure, distribution
>>> and/or copying of this communication is strictly prohibited. If you
>>> receive this communication in error, please notify the sender
>> immediately and delete it from your computer.
>>>
>>>
>> The information contained in this communication is proprietary to
>> Israel Aerospace Industries Ltd. and/or third parties, may contain
>> confidential or privileged information, and is intended only for the
>> use of the intended addressee thereof. If you are not the intended
>> addressee, please be aware that any use, disclosure, distribution
>> and/or copying of this communication is strictly prohibited. If you
>> receive this communication in error, please notify the sender immediately and delete it from your computer.
>>
>>
>
>
> --
> Steve Gregory
> Kimco Design and Manufacturing
> Process Engineer
> (208) 322-0500 Ext. -3133
>
> --
>
>
>
> This email and any attachments are only for use by the intended
> recipient(s) and may contain legally privileged, confidential, proprietary or otherwise private information. Any unauthorized use, reproduction, dissemination, distribution or other disclosure of the contents of this e-mail or its attachments is strictly prohibited. If you have received this email in error, please notify the sender immediately and delete the original.
|