Subject: | |
From: | |
Reply To: | |
Date: | Tue, 24 Jan 2017 22:00:07 +0000 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Joyce is absolutely correct, and may I add that the pump hoses must be able to handle the saponifier and the circulation hoses must be able to handle the flux, saponifier, and everything else that goes through them, and an industrial dishwasher may not be able to handle those chemicals.
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Joyce Koo
Sent: Tuesday, January 24, 2017 3:26 PM
To: [log in to unmask]
Subject: Re: [TN] small aqueous wash system
what ever you do, don't get a industry dish washer... the gasket is not intend for sponifier and other chemicals (like flux residue).
jk
> Hi all, is there such a thing as a small aqueous wash system for PCB
> assemblies?
>
> I do a lot of prototypes / small scale production runs here and would
> love a small wash system.
>
> Thanks
> Ken
>
>
>
> ________________________________
>
>
>
> Saturn PCB Design, Inc.
>
> Kenneth J. Wood
>
> Phone: 407-340-2668
>
> email: [log in to unmask] <mailto:[log in to unmask]>
>
> www.saturnpcb.com <http://www.saturnpcb.com>
>
>
>
>
>
|
|
|