https://www.mentor.com/products/mechanical/flotherm/flotherm-pcb/technical-specifications
> look like very effective heat sink, that is part of the reason you have
> difficulty soldering... (few on the net will tell you insufficient ground
> soldering could occur if pre-heat is not long enough... same reason).
> IMHO.
>> Hi All,
>>
>> We have several designs in which we use the thru-hole pad and
>> surrounding
>> etch to act as a heat sink for device heat being transmitted via the
>> component leads. Typically 2 ounce copper and often on 0.090" thick
>> FR-4
>> boards. With the added copper thickness and larger pad area for better
>> "heat sinking" we now introduce greater difficulty in getting a quality
>> solder joint and don't get me started on the increased difficulty in
>> removing a bad component.
>>
>> So my questions are:
>> Is this a common practice?
>> Does it really provide effective device heat sinking?
>>
>> Phil Nutting | HVP Development Engineer | Excelitas Technologies
>> Corp
>>
>> Lab: +1 978.224.4332 | Office: +1 978.224.4152
>> 35 Congress St, Salem, MA 01970 USA
>> [log in to unmask]<mailto:[log in to unmask]>
>> www.excelitas.com<http://www.excelitas.com/>
>>
>>
>> [Excelitas R_emailsig]
>>
>>
>> Please consider the environment before printing this e-mail.
>> ________________________________
>> This email message and any attachments are confidential and proprietary
>> to
>> Excelitas Technologies Corp. If you are not the intended recipient of
>> this
>> message, please inform the sender by replying to this email or sending a
>> message to the sender and destroy the message and any attachments. Thank
>> you.
>>
>