Hi All

First time I've published a question on this forum!!! & a question I've been
meaning to ask for a while, with regards to IPC/WHMA-A-620B.  

 

On the test section, page 19-10, it states - 'crimp tools are not to be used
for longer than 30 days between verification testing', & on page 19-14, it
states - 'when using hand crimp tools, the testing interval SHALL be once
per day for each combination of tool, wire & contact'.

Is this not a contradiction? or am I miss interpreting? 

Regards

Paul

 

Paul Pidgeon [Certified IPC Trainer]



'STEM Training'

* +44 (0)7912 077445