If you can deal with USB interface, I find these are pretty accurate.

http://www.dlpdesign.com/usb/th1.shtml

It uses a Sensirion brand sensor,  SHT11 If I remember correctly.



On Mon, Dec 19, 2016 at 9:05 AM, Joyce Koo <[log in to unmask]> wrote:

> Gurus,
> can anyone suggest a portable humidity meter capable of range 20-90 %RH,
> with reasonable accuracy?  Many thanks in advance.
> Regards,
>               joyce
>



-- 
Brian Stumm
ETS, Inc.
+1-509-276-2015