Hello Mumtaz - I recommend doing the JSTD-002 Surface Mount Simulation Test
(Test S) as the QFN is a SMT component and the testing will provide a
better representative assessment of your production soldering interactions.
Testing SMT components using PTH techniques is valid but the soldering
dynamics can play a role in causing "false negatives" depending on a couple
of solidification factors. That is the reason the JSTD-002 committee added
surface mount testing options for SMT component technologies.

Dave Hillman
Rockwell Collins
[log in to unmask]

On Tue, Jun 21, 2016 at 6:42 PM, Mumtaz Bora <[log in to unmask]> wrote:

> Hello Technet team,
>
> We have a laminate based QFN package with ENIG plating on terminations.
>  Using lead based paste Sn63/Pb37,  we fail solderability test per
> JESD22B102E (dip and Look test) and also per J-STD-002 method B (dip and
> Look test). However,  we passed reflow solderability test using  lead free
> paste (SAC 305) per method JESD22B102E . Due to product requirements, we
> have to use eutectic Sn63/Pb37 solder paste.  The reflow oven is convection
> air . If anyone had this issue and can share some insight or inputs will
> be  much appreciated.
>
>
>   Thank-you,
>   Mumtaz
> 858-795-0112
>
> CONFIDENTIALITY NOTE: The information transmitted, including attachments,
> is intended only for the person(s) or entity to which it is addressed and
> may contain confidential and/or privileged material. Any review,
> retransmission, dissemination or other use of, or taking of any action in
> reliance upon this information by persons or entities other than the
> intended recipient is prohibited. If you received this in error, please
> contact the sender and destroy any copies of this information.
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud service.
> For more information please contact helpdesk at x2960 or [log in to unmask]
> ______________________________________________________________________
>


______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2