Jack,
As others have indicated, most good FR4s will handle going down there just fine. In a prior life back in Minneapolis, we took product down to -65°C to stress test it and the board was never the problem (parts on the other hand.....). If you going for a wide range say -40°C to +80°C on a routine basis, spec a better FR4 material.
One other thing you have to watch out for is that clock rates/edge-rates/timing can get a little faster when one goes colder and slower when you get hotter. So something that works at 0°C or even -20°C may not handle -40°C. Components can also not handle those temps, so a good review needs to be done.
Best,
-Jeffrey
Jeffrey A. Jenkins
Sr. PCB Staff Designer, CID+/CIT
L-3 Communications, Linkabit Division
Work: 858-552-9832
Email: [log in to unmask]
-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Jack Olson
Sent: Wednesday, June 01, 2016 10:36 AM
To: [log in to unmask]
Subject: [TN] FR4 in COLD environments
Has anyone ever heard anything about the reliability of circuit boards in cold environments?
(continuous -40C)
I couldn't find anything on TechNet or in the Printed Circuits Handbook...
thanks,
Jack
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________
|
|
|