Nigel;

Do you have a picture of the ZIF end with the cracked traces?


Mike Lehmicke
Project Engineer
Printed Circuit Products
Molex Incorporated
22 Empire Drive
St. Paul, MN 55103
651-846-7728
[log in to unmask]







-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Nigel Burtt
Sent: Wednesday, April 06, 2016 10:46 AM
To: [log in to unmask]
Subject: Re: [TN] ENIG on flexi PCBs

-- Sent by an external Sender --

Thanks for all the input. I guess I'm not being clear that (and this is 3rd hand info) the ONLY thing changed from the same supplier was thinner nickel and below the IPC limit of 3um, which stopped the cracking . I'm reluctant to agree to an ENIG process outside the IPC-4552 nickel thickness window without understanding the mechanism of why a thinner nickel over copper might make the tracks more forgiving/ductile.From what has been said so far I get the impression that no-one else has decided that reducing the nickel on an ENIG flexi is helpful in improving its ability to be bent.

Like others have said though, there are other ENIG flexi/flexi-rigid with zif ends around and don't see a problem - some with stiffener some without. The finished circuits do get formed quite tightly in the product and this isn't normally a major problem.

What I was also keen to know was if we did allow this what impact would we expect if we, say, spec'd the low end of the IPC range (ie to be typically only 3um) to have on other performance characteristics, eg solderability, compared with the standard 3-6um range allowed.

________________________________



CONFIDENTIALITY NOTICE: This message (including any attachments) may contain Molex confidential information, protected by law. If this message is confidential, forwarding it to individuals, other than those with a need to know, without the permission of the sender, is prohibited.

This message is also intended for a specific individual. If you are not the intended recipient, you should delete this message and are hereby notified that any disclosure, copying, or distribution of this message or taking of any action based upon it, is strictly prohibited.

English | Chinese | Japanese
www.molex.com/confidentiality.html

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2