twist two wires together and use spot weld to form a small ball  (no  
solder), the potential  difference between the two material   is the  
one that measure the temperature.  you can attach the thermocouple  
use tape or physical clip (not at the junction you just formed by the  
spot weld), clip to the area you want to measure.  my 1.45 cents
  jk
On Mar 8, 2016, at 8:14 AM, Bob Wettermann wrote:

> Morning All:
>
> Has anyone had success in soldering Type K Thermocouples to a PCB. The
> assembly call for a SAC305 no clean alloy....
>
> There are 2 THole connections that will need to be hand-soldered as  
> part of
> this assembly.
>
> Thanks!
>
>
> ______________________________________________________________________
> This email has been scanned by the Symantec Email Security.cloud  
> service.
> For more information please contact helpdesk at x2960 or  
> [log in to unmask]
> ______________________________________________________________________
> -- 
> Bob Wettermann
> BEST Inc
> [log in to unmask]
> Cell: 847-767-5745


______________________________________________________________________