TECHNET Archives

October 2015

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Deng RongJun <[log in to unmask]>
Reply To:
TechNet E-Mail Forum <[log in to unmask]>, Deng RongJun <[log in to unmask]>
Date:
Thu, 8 Oct 2015 09:26:30 +0000
Content-Type:
text/plain
Parts/Attachments:
text/plain (1 lines)

Thanks for comments. 
IPC-6012C 3.10.12  have defined that the unsupported component hole land shall withstand 2kg or 35 kg/cm2, whichever is less. I think it is too lower. 
What about SMT land? Normally, which value shall withstand if tested in accordance with IPC-TM-650 2.4.8?

 
RongJun Deng
Electronics Engineer
Design Link
BB Electronics (Suzhou) Co., Ltd., EMS - from idea to solution

Block E, No.58 Yangdong Road, Loufeng, Suzhou Industrial Park- 215122 Suzhou - P.R.China
Office:  +86 512 6956 2880 - Direct:  +86 512 6956 0125     - Fax:  +86 512 6715 7266
-----Original Message-----
From: Chris Mahanna [mailto:[log in to unmask]] 
Sent: Thursday, October 01, 2015 12:06 AM
To: TechNet E-Mail Forum <[log in to unmask]>; Deng RongJun <[log in to unmask]>
Subject: RE: Land bond strength on rigid board

The IPC SMT land bond strength test method was cancelled due to
1) uncertainty of the method
2) ultimate tensile strength doesn't model the actual failure mode risks very well

Note that:
2.4.1 has much lower uncertainty because it provides a circular land, with hole to build ideal attachment geometry.
Ultimate tensile is not useless data, but peel strength (IPC-TM-650 2.4.8) is generally considered a better model of foil adhesion to laminate.

Chris Mahanna
Robisan Laboratory Inc.

-----Original Message-----
From: TechNet [mailto:[log in to unmask]] On Behalf Of Deng RongJun
Sent: Monday, September 28, 2015 6:45 AM
To: [log in to unmask]
Subject: [TN] Land bond strength on rigid board

Hi Experts:

Is there have a standard for SMT Land bond strength test? What about the formula for force calculation?
Can I use “IPC-TM-650 2.4.21 Land Bond Strength, Unsupported Component Hole” for reference?




Best regards

RongJun Deng
Electronics Engineer
Design Link




______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] ______________________________________________________________________

______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask] 
______________________________________________________________________

ATOM RSS1 RSS2