Would anyone like to share their thoughts on automated coating inspection?
The good, the bad and or the ugly.
Initial experience that I have had with them leaves me with the impression that:
> That are useful to indicate if there is complete lack of coating on a PCA or some specific PCA regions.
> can indicate if there is sizable (ytbd) violation of a keep out zone.
> not the best to verify coverage on some items such as fine pitch QFP leads or other small SM type components
> except for the case of select spots on a PCA also not the best to use as general tool to locate thick fillets or thin coatings on a PCA
As I said above, any thoughts (profound, rants or other) on this matter would be appreciated.
Thanks in advance
Rich Kraszewski /PLEXUS
______________________________________________________________________
This email has been scanned by the Symantec Email Security.cloud service.
For more information please contact helpdesk at x2960 or [log in to unmask]
______________________________________________________________________