I would like to ask anyone if there are any reliability data regarding 
the evaluation of voiding in a solder ball (BGA).

In both the standards IPC-7095C and IPC-A-610F, the voiding in the 
solder balls is evaluated measuring the area of the voids. However, the 
weakening of balls caused by voiding should depend on the amount of the 
missing material caused by the presence of voids. If this is true, the 
amount of the missing material should be measured by the total *volume* 
of voids, not by the area. Consequently, the limit should be set on the 
volume, instead of the area.

For example, with the present rule based on the percentage of area of 
the voids, a solder ball of 0,85 mm diameter, with a single void of 0,45 
mm diameter, is acceptable, since the percentage of voiding is 28%, thus 
less than the maximum limit of 30% (ref. IPC-A-610F). In this case, the 
missing volume of the material is 15%.

Considering another example, if a solder ball has 6 voids of a 0,20 mm 
diameter each, giving 33% of the area of voiding, would be rejected. 
However, in this last case the percentage of the missing volume is only 
8%, i.e. less than the previous case (about 53% of the previous case!).

So, the ball of the second case is rejected, even if it stronger that 
the one of the first case. On the contrary, it is the solder ball of the 
first case that should be rejected.

Enrico

-- 
Enrico Galbiati
Consulenza Affidabilitą e Normative
Via Kennedy Ingresso 2, 20871 Vimercate (MB) - Italy
Desk: +39.039.8908.4547 - Fax: +39.039.8908.5051 - Mobile: +39.335 6833616